Aftercure
Tools preparation
- a) Shovel
- b) Blade
- c) Gloves
- d) Napkin
- e) Trash can
- f) Squeeze bottle
- g) Plastic box with lid * 4
- h) Alcohol
4 plastic boxes, one is used to store contaminated shovel and blade, one is
used to place the model, one is used to fill alcohol for cleaning, one is used to
fill alcohol for rinse.
Squeeze bottle filled with alcohol
Operation notice
a) Wearing glasses or goggles is necessary, if the resin or alcohol splash into
your eyes accidentally, you should wash your eyes with water immediately and
seek medical treatment urgently.
b) Gloves must be worn when you touch things that stained with resin.
c) The bottom of the build platform must face up when you holding the build
platform with printed models.
d) All containers and trash can must have lid, they should be covered after
use.
e) Tools stained with resin must be stored in container.
f) Keep the gloves clean at all times, clean or replace the gloves if they stained
with resin.
g) Used paper and gloves must be put into the trash can in time.
h) In order to reduce the VOC release, keep the environment clean, the resin
that accidentally dropped or splashed should be erased in time and clean the
contaminated surface with alcohol.
Operation procedure
A. When printing is finished, open the protective casing, wipe off the liquid
resin that attached to the model and build platform.
B. Unlock the build platform, using your right hand to stabilize the printer, using
your left hand to remove the build platform.
a) Shovel the failed models into the trash directly
b) If the model is still attached with liquid resin, use the trash can to collect, use
the squeeze bottle to wash the model. Remove the liquid resin as much as
possible and then wipe dry with tissue.
C. Remove the model from the build platform.
a) For the model only touch supports, remove the model from the supports, put
it in the container. Remove the remaining supports directly in the trash can.
b) For the model with supports or none supports, use the blade to remove the
model, put it in the container.
D. Clean up the residue on the build platform, wipe off with napkin, and return it
to the printer
E. Clean the model
a) Use the diagonal pliers to remove the remaining supports on the model.
b) Wash the models in the container for cleaning, remove the semi-solidified
resin on the model surface by hand or brush
c) Rinse the model in the container, the model surface is subject to none
creamy touch
d) Dry the model with napkin
e) Do not immerse the model in alcohol and take out immediately after
cleaning
F. Drying model
a) Dry in the sun or dry the model with a fan, the surface should be completely
dry without liquid
b) Operate in a ventilated environment or equipped with activated carbon
adsorption device cleaning
G. Curing model
a) Use a light source at a wavelength of 415 nm or less than 415 nm for curing
b) The required curing time is in connection with the intensity of the light
source, the new light source should be tested on the model in order to get
appropriate curing time.